  "url": "https://openlegislation.uk/eu-decision-2013-107/schedule-ANNEX C/division-III./division-D./division-2./division-(d)/division-(ii)",
  "json_url": "https://openlegislation.uk/eu-decision-2013-107/schedule-ANNEX C/division-III./division-D./division-2./division-(d)/division-(ii).json",
  "legislation": "eudn/2013/107",
  "legislation_title": "Council Decision of 13 November 2012 on the signing and conclusion of the Agreement between the Government of the United States of America and the European Union on the coordination of energy-efficiency labelling programmes for office equipment (Text with EEA relevance) (2013/107/EU)",
  "legislation_url": "https://openlegislation.uk/eu-decision-2013-107",
  "path": "schedule/ANNEX C/division/III./division/D./division/2./division/(d)/division/(ii)",
  "kind": "division",
  "number": "(ii)",
  "heading": "Procedure for Copiers, Digital Duplicators and MFDs without Print Capability",
  "text": "Table 7\nTEC Test Procedure — Copiers, Digital Duplicators and MFDs without Print Capability\nStep\nInitial State\nAction\nRecord (at end of step)\nPossible States Measured\n1\nOff\nPlug the unit into meter. Zero the meter; wait test period (five minutes or more).\nOff energy\nOff\nTesting Interval time\n2\nOff\nTurn on unit. Wait until unit indicates it is in Ready mode.\n—\n—\n3\nReady\nCopy a job of at least one image but no more than a single job per Job Table. Record time to first sheet exiting unit. Wait until the meter shows that the unit has entered its final Sleep mode.\nActive0 time\n—\n4\nSleep\nZero meter; wait one hour. If unit turns Off in less than one hour, record time and energy in Sleep, but wait full hour before moving to Step 5.\nSleep energy\nSleep\nTesting Interval time\n5\nSleep\nZero meter and timer. Copy one job per Job Table. Record time to first sheet exiting unit. Wait until timer shows that 15 minutes have elapsed.\nJob1 energy\nRecovery, Active, Ready, Sleep, Auto-off\nActive1 time\n6\nReady\nRepeat Step 5.\nJob2 energy\nSame as above\nActive2 time\n7\nReady\nRepeat Step 5 (without Active time measurement).\nJob3 energy\nSame as above\n8\nReady\nRepeat Step 5 (without Active time measurement).\nJob4 energy\nSame as above\n9\nReady\nZero meter and timer. Wait until meter and/or unit shows that unit has entered its Auto-off mode.\nFinal energy\nReady, Sleep\nFinal time\n10\nAuto-off\nZero the meter; wait test period (five minutes or more).\nAuto-off energy\nAuto-off\nOriginals may be placed in the document feeder before the test begins. Products without a document feeder may make all images from a single original placed on the platen.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/eudn/2013/107/schedule/ANNEX C/division/III./division/D./division/2./division/(d)/division/(ii)",
    "retrieved_at": "2026-11-01T15:15:09.798475+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}